Oversetter...
F2008

RL The motor type has changed

Bosch Rexroth · IndraDrive MPx02

Hva betyr F2008 ?

This non-fatal error on the IndraDrive MPx02 indicates that the motor type connected to the drive has changed, or the drive has detected a discrepancy between the configured motor type and the actual motor connected. This often happens after a motor replacement or if motor data parameters are mismatched.

Vanlige årsaker

  • Physical replacement of the motor with a different type without updating drive parameters.
  • Incorrect motor type selection or parameterization in the IndraDrive MPx02 (e.g., P-0-0000, P-0-0001).
  • Motor encoder feedback mismatching the expected motor configuration.
  • Drive's internal auto-detection mechanism indicating a motor type change.
  • Corrupted motor parameter data in the IndraDrive MPx02 memory.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Verify the actual motor type and compare it against the motor parameters configured in the IndraDrive MPx02 (e.g., P-0-0000 'Motor type', P-0-0001 'Motor IDN').

  2. 2

    If the motor has been replaced, update the motor parameters in the IndraDrive MPx02 to match the new motor's nameplate data.

  3. 3

    Ensure the motor encoder is correctly connected and providing valid feedback that is consistent with the motor type.

  4. 4

    Perform a motor identification or auto-tuning procedure to allow the drive to recognize and adapt to the connected motor.

  5. 5

    Reload the last known good parameter set for the motor, or manually re-enter all motor data from the nameplate.

Se alle koder i denne manualen (99)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kilde: Bosch Rexroth IndraDrive MPx02