Oversetter...
F2006

MMC was removed

Bosch Rexroth · IndraDrive MPx02

Hva betyr F2006 ?

This non-fatal error indicates that the MultiMediaCard (MMC), which typically stores drive parameters and firmware, has been removed from the IndraDrive MPx02 while the drive was powered on or during an operation requiring its presence. This disrupts access to critical data.

Vanlige årsaker

  • MMC physically removed from the drive slot while the drive was operating.
  • Loose or improperly seated MMC causing intermittent contact.
  • Faulty MMC card that is unreadable or intermittently fails.
  • Vibrations or mechanical shock causing the MMC to dislodge.
  • Dust or debris in the MMC slot preventing proper contact.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Power off the IndraDrive MPx02 completely before attempting to re-insert or remove the MMC.

  2. 2

    Ensure the MMC is correctly and securely seated in its slot, verifying any latching mechanisms.

  3. 3

    Inspect the MMC card for physical damage or contamination. Try cleaning the contacts with an appropriate cleaner.

  4. 4

    If the MMC appears damaged or the error persists, attempt to use a new or known-good MMC with the correct data.

  5. 5

    Check for excessive vibrations or mechanical stress on the drive that might dislodge the MMC.

Se alle koder i denne manualen (99)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kilde: Bosch Rexroth IndraDrive MPx02