E8043
Positive travel range limit switch activated
Bosch Rexroth · IndraDrive C Drive Controllers
Hva betyr E8043 ?
The positive hardware travel limit switch has been activated, indicating that the axis has reached its maximum physical travel in the positive direction. This typically results in a controlled stop.
Vanlige årsaker
- Programmed motion or jog command caused the axis to activate the positive limit switch.
- Incorrectly set software limits, allowing motion to reach the hardware limit.
- Mechanical overtravel due to inertia or incorrect braking after the software limit.
- Faulty positive limit switch or its wiring.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Manually jog the axis in the negative direction to clear the limit switch and return to a safe operating range.
- 2
Verify the positive software travel limit parameter in the drive controller and adjust it to be inside the hardware limit.
- 3
Inspect the positive limit switch for physical damage, proper mounting, and verify its wiring for continuity.
- 4
Check the motion program for any commands that might cause the axis to intentionally or unintentionally hit the limit switch.
Verifisert teknisk data. Sist oppdatert: March 2026