E8040

Torque/force actual value limit active

Bosch Rexroth · IndraDrive C Drive Controllers

Hva betyr E8040 ?

The actual torque or force developed by the motor has reached its configured limit. This warning indicates that the motor is operating at its maximum allowed output for torque/force.

Vanlige årsaker

  • Motor running under excessive mechanical load, causing it to reach its torque limit.
  • Torque limit parameter set too low for the application requirements.
  • Mechanical binding or obstruction in the system, increasing required torque.
  • Drive parameter for current/torque limit incorrectly set.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Verify the mechanical load on the motor and ensure it is within the continuous torque capability of the motor and drive.

  2. 2

    Check the drive's torque limit parameter and adjust if necessary, ensuring it is appropriate for the application.

  3. 3

    Inspect the mechanical system for any binding, misalignment, or excessive friction that could increase the required torque.

  4. 4

    Monitor the actual motor current and torque values during operation to understand the load conditions.