E2829

Not ready for power on

Bosch Rexroth · IndraDrive C Drive Controllers

Hva betyr E2829 ?

The drive is unable to transition to the 'power on' state. This usually indicates a prerequisite for enabling the power section has not been met.

Vanlige årsaker

  • Internal diagnostics or self-tests not completed successfully.
  • Safety circuits (e.g., Safe Torque Off) are not released.
  • Control voltage (24VDC) supply issue.
  • Parameter errors preventing power section enablement.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check for any other active warning or fault messages that might be preventing readiness.

  2. 2

    Verify that the 24VDC control power supply is present and stable at the drive's control terminals.

  3. 3

    Ensure that all safety circuits are correctly wired, closed, and released, allowing the drive to enable its power section.

  4. 4

    Cycle power to the drive controller to attempt a full re-initialization.