E2816

Undervoltage in power section

Bosch Rexroth · IndraDrive C Drive Controllers

Hva betyr E2816 ?

The DC bus voltage in the drive's power section has dropped below the minimum acceptable threshold. This indicates insufficient power available for motor operation.

Vanlige årsaker

  • Insufficient incoming AC mains voltage (see E2814).
  • Excessive load causing a momentary drop in DC bus voltage.
  • Faulty rectifier stage or pre-charge circuit in the drive.
  • Internal power supply issue within the drive.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Measure the incoming AC mains voltage at the drive's input terminals and ensure it is stable and within specified limits.

  2. 2

    Check the DC bus voltage at the +UDC/-UDC terminals on the drive during operation and ensure it remains above the undervoltage threshold.

  3. 3

    Verify that the drive is correctly sized for the motor and application load, avoiding momentary overloads.

  4. 4

    Inspect the pre-charge resistors and contactors/relays for proper functionality if the fault occurs during power-up.