E2056
Torque limit = 0
Bosch Rexroth · IndraDrive C Drive Controllers
Hva betyr E2056 ?
The torque limit parameter is set to zero, preventing the motor from generating any torque. This causes the drive to be unable to move or hold position.
Vanlige årsaker
- Torque limit parameter was intentionally or accidentally set to 0.
- External PLC or HMI command setting the torque limit to 0.
- System logic error preventing the torque limit value from being set above 0.
- Emergency stop or safety function that reduces the torque limit to zero.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Verify the torque limit parameter in the drive controller and ensure it is set to a non-zero, appropriate value for the application.
- 2
Check the machine's HMI or control program for any active torque limit settings that might be forced to 0.
- 3
Trace the logic controlling the torque limit to ensure no unexpected conditions are setting it to zero.
- 4
Check if any active safety functions or emergency stops are causing the torque limit to be set to zero. Resolve the safety condition if present.
Verifisert teknisk data. Sist oppdatert: March 2026