xxxx 0011
Invalid Connection ID
Beckhoff · TwinSAFE Logic FB
Hva betyr xxxx 0011 ?
The FSoE connection ID used in communication is invalid or does not match the expected ID configured in the devices. This prevents the establishment or continuation of a secure safety connection, rendering the system inoperable due to a breakdown in trusted communication.
Vanlige årsaker
- Invalid Connection Identifier (ID) received.
- Attempted to communicate with a non-existent or wrong device ID.
- Network configuration error.
- Incorrectly assigned communication address.
- Duplicated Connection IDs on the network.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Verify the FSoE connection ID is correctly configured and identical on both the master and slave devices.
- 2
Check the network topology and ensure no duplicate FSoE connection IDs exist within the safety domain.
- 3
Reinitialize the FSoE connection to ensure IDs are properly synchronized.
- 4
Consult the device manual for specific FSoE connection ID setup procedures.