Muting Input 3/4 Discrepancy Not Reset
Beckhoff · TwinSAFE Logic FB
Hva betyr FB MUTING Bit 10 ?
A discrepancy error in 'MuteIn3'/'MuteIn4' was detected and has not yet been acknowledged or reset. This indicates a persistent underlying issue with muting input group 2 that needs active resolution and acknowledgment before normal operation can resume. The system will remain in a safe, stopped state.
Vanlige årsaker
- Muting input 3 or 4 discrepancy not reset.
- Safety light curtain muting signal conflict.
- Muting sensors reporting inconsistent states.
- Muting signal lost while safety function is active.
- External muting logic not acknowledged.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Address the root cause of the 'MuteIn3'/'MuteIn4' discrepancy (refer to troubleshooting for 'FB MUTING Bit 2').
- 2
Ensure the error is acknowledged via the 'ERR_ACK' input of the related TwinSAFE group after rectifying the fault.
- 3
Verify that the physical conditions causing the discrepancy are no longer present (e.g., sensor issue resolved, wiring fixed).
- 4
Monitor the 'MuteIn3' and 'MuteIn4' signals to confirm stable, synchronized operation after troubleshooting.