Oversetter...
25
OverSpeed Limit
Allen-Bradley · PowerFlex 700
Hva betyr 25 ?
Functions like Slip Compensation or Bus Regulation have attempted to add an output frequency adjustment greater than that programmed in [Overspeed Limit]. This occurs when the drive tries to exceed its configured maximum speed due to an external force (overhauling load) or control algorithm, potentially leading to instability.
Vanlige årsaker
- Motor speed exceeds the configured overspeed limit (e.g., P3-02).
- Runaway motor condition due to loss of control.
- Incorrect encoder feedback indicating higher speed than actual.
- External control signal commanding excessive speed.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Remove excessive load or overhauling conditions on the motor.
- 2
Increase the value of the [Overspeed Limit] parameter.
Verifisert teknisk data. Sist oppdatert: March 2026
Relaterte feilkoder
Kilde: Allen-Bradley PowerFlex 700