Boot error code (Various)
ABB · Application Error ABB Motion Drives Error trouble shoo
Hva betyr b06411 - b13066 ?
The drive displays a boot error code (starting with 'b' on the seven-segment display) indicating a fatal error during the boot-up process. This generally points to issues with the memory module, firmware, or connected external hardware.
Vanlige årsaker
- Memory module not correctly fitted or damaged.
- Corrupt firmware preventing successful boot-up.
- Damaged encoder drawing down the control board voltage, causing boot failure.
- Other connected external hardware interfering with the boot process.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Power down the drive, then remove and re-seat the memory module, ensuring it is correctly fitted.
- 2
Disconnect all connections apart from the logic supply power source.
- 3
Specifically, remove the encoder connection, as a damaged encoder can drag the control board voltage down.
- 4
Power up the drive again after performing the above steps.
- 5
If the problem persists, replace the memory module. If still unresolved, replace the drive unit.