Oversetter...
30010
Fan is not operating correctly
ABB · Application Error ABB Motion Drives Error trouble shoo
Hva betyr 30010 ?
The drive (MotiFlex e180, MicroFlex e190) has detected that an internal cooling fan has failed or is not operating as expected.
Vanlige årsaker
- Blocked fan inlets or outlets on the bottom of the drive, preventing airflow.
- Mechanical failure of the fan motor or bearings, causing the fan to stop rotating.
- Accumulation of dust and debris on the fan blades or housing, hindering rotation.
- An electrical fault in the fan circuit or wiring.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Check the bottom of the drive to ensure the fan inlets are not blocked by debris or external objects.
- 2
Visually inspect the fan to determine if it is rotating freely when the drive is powered on or attempting to operate.
- 3
Clean any accumulated dust or foreign material from the fan blades and housing to ensure unobstructed rotation.
- 4
If the fan does not turn despite being clear of obstructions, it indicates a hardware failure of the fan itself. Contact ABB for a replacement fan specific to the drive model.
Verifisert teknisk data. Sist oppdatert: March 2026
Relaterte feilkoder
Kilde: Application Error ABB Motion Drives Error trouble shoo