246
Event not present/installed
ABB · Application Error ABB Motion Drives Error trouble shoo
Hva betyr 246 ?
The Mint program attempted to reference an event that is not present, has not been installed, or is undefined in the controller (MotiFlex e100, MotiFlex e180, MicroFlex e190).
Vanlige årsaker
- Referencing a non-existent or undefined event within the Mint program.
- A typographical error in the event name used in the Mint program.
- A required event definition or library file is missing or not loaded.
- Attempting to use an event that is not supported by the current firmware version.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Amend the Mint program to ensure that all referenced events are correctly defined and installed.
- 2
Double-check the spelling and syntax of the event name in the Mint program against its official definition.
- 3
Verify that any necessary event libraries or modules are loaded and accessible by the program.
- 4
Consult the Mint programming manual or drive documentation to confirm the correct declaration and usage of events.