E39
Compressor Discharge Temperature Sensor (THOD) Defective
Mitsubishi Electric · R410A Systems
What does E39 mean?
The compressor discharge temperature sensor (THOD) is defective (resistance is open circuit) or has a poor connection to the outdoor unit PCB. This prevents accurate monitoring and protection of compressor discharge temperature, risking compressor damage.
Repair Steps
- 1
Measure the resistance of the THOD sensor at its leads — compare to a resistance-temperature chart if available.
- 2
Inspect the THOD sensor's connector on the outdoor unit PCB — verify it is securely seated and free from corrosion.
- 3
Check for damage to the sensor wiring between the sensor and the PCB using a multimeter for continuity.
Verified technical data. Last updated: March 2026