E9

Outdoor Unit Communication Receive Error

Mitsubishi Electric · PAR-21MAA MA Remote Controller

What does E9 mean?

The outdoor unit has detected an error in receiving communication signals from the indoor unit. This indicates a problem with the data transmission path from the indoor unit or the outdoor unit's receiving circuit, leading to a loss of outdoor unit control.

Repair Steps

  1. 1

    Verify the indoor/outdoor connecting wire terminations match the wiring diagram for correct connection.

  2. 2

    Inspect the indoor/outdoor connecting wire and power supply for signs of electrical noise interference that could disrupt signal reception.

  3. 3

    Cycle power to the unit (turn off, then on again) to re-check for the error.