E.OP1 to OP3

Option slot alarm

Mitsubishi Electric · A500 Inverter

What does E.OP1 to OP3 mean?

This alarm stops the inverter output if a functional alarm occurs in the plug-in option loaded in the corresponding slot (1, 2, or 3). Examples include communication alarms for communication options or contact faults for other types of plug-in options.

Repair Steps

  1. 1

    Confirm the option function settings and operation for the respective option slot.

  2. 2

    Ensure the plug-in option in slot 1, 2, or 3 is connected securely to its connector.

  3. 3

    Check the communication cable associated with the option for wire breakage.

  4. 4

    Verify that the termination resistor for the communication option is fitted properly.