111

H11

Lenze · 9300 Series

What does 111 mean?

The temperature sensor inside the controller is indicating undefined values. This suggests a fault with the sensor or its connection, leading to unreliable internal temperature monitoring.

Common Causes

  • Internal temperature sensor (e.g., integrated thermistor, IC sensor) on the control board has failed.
  • Faulty solder joint or internal connector linking the sensor to the drive's analog-to-digital converter (ADC) input.
  • Unstable or incorrect internal power supply voltage to the sensor or its reference circuitry.
  • Severe electromagnetic interference (EMI) affecting the sensitive analog input circuitry for the internal temperature sensor.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    1. Power cycle the drive and observe if the fault clears; sometimes transient conditions can trigger it.

  2. 2

    2. Verify the ambient operating temperature within the control cabinet is within the drive's specified range (e.g., 0-50°C).

  3. 3

    3. Inspect the control board for any visible signs of overheating, component damage, or abnormal odors.

  4. 4

    4. Perform a factory reset of drive parameters (e.g., Parameter P0-02 = 1) and re-download the configuration, then re-evaluate.

  5. 5

    5. Contact the drive manufacturer's technical support for potential control board replacement, providing the specific fault code and drive serial number.

Browse all codes in this manual (145)
Verified technical data. Last updated: March 2026

Related Faults