Fuse Defective

Cabinet Control Unit Fuse Defective

Kuka · Sunrise Cabinet Med Controller

What does Fuse Defective mean?

A red LED next to a fuse on the Cabinet Control Unit, Small Robot (CCU_SR) is ON, indicating that the specific fuse is defective. Defective fuses interrupt the power supply to their respective circuits, potentially disabling critical components or sections of the robot control system. This requires immediate attention to restore functionality.

Repair Steps

  1. 1

    Identify the specific fuse by locating the illuminated red LED next to it.

  2. 2

    After eliminating the underlying cause of the fuse blowing, replace the defective fuse with a new one of the exact specified value, either printed on the module or listed in the Instructions for Use (e.g., 32 V/2 A for F17-2 inputs CCU_SR).

Browse all codes in this manual (21)
Verified technical data. Last updated: March 2026
Source: Kuka Sunrise Cabinet Med Controller
Kuka Error Fuse Defective: Cabinet Control Unit Fuse Defective — Troubleshooting Guide | ErrorLib