11001

Connection to device terminated

Kuka · ProfiNet Controller/Device 3.1

What does 11001 mean?

The PROFINET connection to the specified device ({Name}) has been terminated. This fault indicates an interruption in the device's power supply or a physical break in the network connection, leading to a complete loss of communication.

Repair Steps

  1. 1

    Verify the power supply to the PROFINET device {Name} by checking voltage at its power terminals.

  2. 2

    Inspect the network cable connected to device {Name} for any physical damage, loose connections, or disconnections at both ends.

  3. 3

    Check network switch port status connected to device {Name} to confirm link activity.

Browse all codes in this manual (13)
Verified technical data. Last updated: March 2026
Source: Kuka ProfiNet Controller/Device 3.1