Ackn. Max. following error exceeded ({Drive})
Kuka · KSS 8.3 System Software
What does 26024 mean?
The maximum permissible following error for the specified drive has been exceeded. This indicates a significant deviation between the commanded position and the actual position of the axis. While undesirable in normal operation, this monitoring function may be deactivated using `SET_TORQUE_LIMITS(..., monitor #off)` when operating in torque mode to prevent spurious errors.
Repair Steps
- 1
Identify the specific drive mentioned in the error message to pinpoint the affected axis.
- 2
If the robot is operating in torque mode, verify that the `SET_TORQUE_LIMITS()` function is correctly configured with `monitor #off` if this monitoring is not desired.
- 3
In normal operation, check for mechanical obstructions, excessive load, or incorrect motion parameters that could cause large following errors.
- 4
Inspect the motor, gearbox, and position feedback device for the affected drive for any signs of damage or malfunction.