1100

Stopped {(Axis number)}

Kuka · KSS 8.3 System Software

What does 1100 mean?

This message indicates that a specific axis has stopped unexpectedly. This is a regular monitoring function that can be triggered if an axis is prevented from moving or maintaining its commanded position. In torque mode, this monitoring may be automatically deactivated if `SET_TORQUE_LIMITS()` is used with `monitor #off`.

Repair Steps

  1. 1

    Identify the specific axis number mentioned in the error message.

  2. 2

    Physically inspect the robot's axis for any obstructions, external forces, or mechanical binding preventing movement.

  3. 3

    Review the robot program and motion parameters for the affected axis to ensure valid commands and trajectories.

  4. 4

    If operating in torque mode and this message is not desired, confirm that `SET_TORQUE_LIMITS(..., monitor #off)` is correctly implemented for the axis.

Browse all codes in this manual (6)
Verified technical data. Last updated: March 2026
Source: KUKA KSS 8.3 System Software
Kuka Error 1100: Stopped {(Axis number)} — Troubleshooting Guide | ErrorLib