2948

Ackn. force controller error

Kuka · KRC2 KSS System Message

What does 2948 mean?

This is a follow-up message to the 'Force controller error' indicating that the force sensor signal does not match the motion. Error type 1: Actual force changes but position remains constant. Error type 2: Position changes but actual force remains constant. Error type 3: The gun opens further than the position corresponding to FORCE_LIM. These monitoring functions are only active during force control, resulting in dynamic braking, inhibition of active commands, and the 'ALARM_STOP' signal at level 0.

Repair Steps

  1. 1

    Acknowledge the message.

  2. 2

    Check the force sensor for proper operation and signal integrity.

  3. 3

    Check the force sensor cable for damage or loose connections.

  4. 4

    Check the RDC plug-on card for proper installation and functionality.

Browse all codes in this manual (36)
Verified technical data. Last updated: March 2026
Source: Kuka KRC2 KSS System Message