122

LV2-Trip (Battery undervoltage, U<22 V)

Kuka · KR C2 Robot Controller

What does 122 mean?

This fault indicates a battery undervoltage condition where the battery voltage has dropped below 22V (KPS-600). This is critical for maintaining volatile memory or providing backup power, and sustained low voltage can lead to data loss or operational issues.

Repair Steps

  1. 1

    Measure the battery voltage directly at its terminals — expect >22V.

  2. 2

    Verify the battery charger is functioning correctly and providing adequate charge current.

  3. 3

    Check battery terminal connections for corrosion or looseness.

Browse all codes in this manual (54)
Verified technical data. Last updated: March 2026