1019

LOGIC FAILURE #1

Kone · Elevator Control

What does 1019 mean?

A logic failure of type #1 has occurred in the motor controller (codes 1019, 2019, 3019). This indicates an internal control logic error, preventing correct operation. The specific lift reaction is controller dependent.

Common Causes

  • Internal controller logic processing error.
  • Corrupted program memory or runtime data.
  • Hardware fault affecting logic circuits or CPU functionality.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify main AC/DC supply voltage to the motor controller input terminals against nominal specifications and stability.

  2. 2

    Check and compare current operational parameters and configuration settings of the motor controller against the documented system backup or factory defaults.

  3. 3

    Inspect and verify the operational status of critical inputs such as encoder feedback, limit switches, and safety circuit signals via the controller's diagnostic interface.

  4. 4

    Perform a controlled power cycle of the motor controller after safely stopping the elevator, observing for recurrence of the error.

Browse all codes in this manual (60)
Verified technical data. Last updated: March 2026