101

Gateway CAN Connect Timeout

Fronius · Perfect Charging

What does 101 mean?

The 'CAN Connect' setting is active on the charger, but no CAN connection could be established to the gateway device for a continuous period of at least 2 minutes. This means the charger cannot exchange data with the gateway, which is critical for remote monitoring or control.

Common Causes

  • A disconnected or physically damaged CAN bus cable between the charger and the gateway device.
  • The gateway device is not powered on, has crashed, or is otherwise faulty and unable to respond to CAN communication.
  • Incorrect CAN bus settings (e.g., baud rate, termination) or an addressing conflict between the charger and the gateway.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify the physical CAN bus cable connection between the charger and the gateway device for integrity and secure mating.

  2. 2

    Ensure the gateway device is powered on and operating correctly by checking its indicator LEDs or internal diagnostics.

  3. 3

    Check CAN bus termination resistor values and configuration settings on both the charger and the gateway to ensure they are correctly set for the network topology.

Browse all codes in this manual (61)
Verified technical data. Last updated: March 2026

Related Faults

Fronius Error 101: Gateway CAN Connect Timeout — Troubleshooting Guide | ErrorLib