PS5073
NO DECIMAL POINT
Fanuc · Series 0i-MODEL F Plus Parameter
What does PS5073 mean?
This program error alarm is issued when a command, particularly for an extended axis name or within an execution macro, is specified without a decimal point in an address where one is required. This check is active if parameter 3404 bit #1 (POL) is set to 1.
Repair Steps
- 1
Check parameter 3404 bit #1 (POL). Verify that it is set to 1, which enables the decimal point omission check.
- 2
Review the NC program block that caused the alarm. Locate the command that lacks a decimal point in an address where one is expected, paying close attention to extended axis names or execution macro commands.
- 3
Modify the NC program to include the decimal point in the identified command.