DS1448

Scale Area Exceeded

Fanuc · Series 0i-MODEL F Plus Parameter

What does DS1448 mean?

This alarm is issued if parameter settings for the scale area on the affected axis cause it to extend across the scale zero point or base point. This indicates an invalid configuration for the linear scale with absolute address reference marks or an absolute address zero point. Parameters 1883 and 1884 are typically involved in defining this area.

Repair Steps

  1. 1

    Check the values of parameter No. 1883 and parameter No. 1884 for the affected axis.

  2. 2

    Adjust parameter settings to ensure the defined scale area does not extend beyond the physical scale zero point or base point.

Browse all codes in this manual (13)
Verified technical data. Last updated: March 2026
Source: FANUC Series 0i-MODEL F Plus Parameter