SP1996

ILLEGAL SPINDLE PARAMETER SETTING

Fanuc · Series 0i-D/0i Mate-D Maintenance

What does SP1996 mean?

This Fanuc Series 0i-D/0i Mate-D spindle alarm indicates an incorrect spindle assignment or that the number of configured spindles exceeds the system's maximum allowance. Parameters 3701#1, #4, 3716, and 3717 are typically involved.

Common Causes

  • Incorrect assignment of spindle axes in parameters (e.g., Parameter No.3701#1, #4).
  • The total number of spindles configured (Parameter No.3716) exceeds the system's maximum capacity.
  • Parameter No.3717 (spindle control type) is incorrectly set for the installed spindle amplifier.
  • Conflicting or inconsistent spindle-related parameter settings.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify Parameter No.3701#1 (spindle axis assignment for axis 1) and No.3701#4 (if applicable for axis 2) are correctly set according to the machine configuration.

  2. 2

    Check Parameter No.3716 (number of spindles for the system) to ensure it does not exceed the maximum allowed for the specific CNC model.

  3. 3

    Confirm Parameter No.3717 (spindle control type) is accurately set corresponding to the installed spindle amplifier and motor type.

  4. 4

    Review all spindle-related parameters against a known good parameter list or the machine's specifications.

  5. 5

    If any parameters are found to be incorrect, adjust them and then cycle power to the CNC system to apply the changes.

Browse all codes in this manual (60)
Verified technical data. Last updated: March 2026

Related Faults

Source: Fanuc Series 0i-D/0i Mate-D Maintenance