+ OVERTRAVEL ( SOFT 3 )
Fanuc · Series 0i-D/0i Mate-D Maintenance
What does IE0005 mean?
This Fanuc Series 0i-D/0i Mate-D malfunction prevention alarm indicates that the stored stroke check 3 on the positive side for an axis has been exceeded. This is a tertiary software limit, typically used for complex tooling or specific safety zones.
Common Causes
- NC program error commanding movement beyond the positive software limit 3.
- Incorrect setting of the software limit parameter for positive stroke check 3.
- Physical interference from tooling, workpieces, or machine components triggering the third soft limit.
- Manual jog operation exceeding the defined positive software limit 3.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Examine the NC program for commands that result in the axis exceeding the positive limit of stored stroke check 3.
- 2
Verify the parameter settings for stored stroke limit check 3 on the positive side for the affected axis.
- 3
Inspect for any physical interference from tooling, workpieces, or machine components that trigger this third soft limit.
- 4
Jog the axis in the negative direction to clear the overtravel condition and then reset the alarm.
- 5
Ensure that the tool data and offset values are correctly entered and do not lead to an overtravel condition.