NO OPTION(LADDER STEP)
Fanuc · Series 0i-D/0i Mate-D Maintenance
What does ER07 mean?
This Fanuc Series 0i-D/0i Mate-D PMC alarm indicates that no ladder step count option is found in the system. This can be due to corrupted CNC parameter data or a missing option license.
Common Causes
- The ladder step count option is missing or not activated in the CNC parameters.
- Corrupted backup CNC parameter data leading to loss of option information.
- Missing or incorrectly installed hardware key or software license for the ladder step option.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Attempt to restore the backup CNC parameter data, as PMC option settings are often included within these parameters.
- 2
Verify the existence and correct activation of the ladder step count option in the CNC system parameters.
- 3
Check for any hardware keys or software licenses related to the ladder step count option that might be missing, improperly installed, or corrupted.
- 4
If no option is found or restoration fails, contact FANUC support to inquire about purchasing or activating the appropriate ladder step count option.
- 5
Ensure the PMC hardware is correctly recognized by the CNC system and its configuration parameters.