382
COUNT MISS(EXT)
Fanuc · Series 0i-D/0i Mate-D Maintenance
What does 382 mean?
This alarm on Fanuc Series 0i-D/0i Mate-D indicates a position data count error from a separate (external) detector. This is typically due to a detector failure, signal corruption, or mechanical issues.
Common Causes
- Internal failure of the external detector resulting in incorrect pulse counting.
- Damaged or loose cable leading to intermittent signal loss from the external detector.
- Excessive vibration or mechanical play affecting the external detector's accuracy.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Inspect the external detector's cable and connectors for proper seating, damage, or loose connections.
- 2
Verify the mechanical mounting of the external detector for stability and correct alignment.
- 3
Check for any excessive vibration or mechanical play in the system that could cause counting errors.
- 4
If physical inspection and mechanical checks do not resolve the issue, replace the external detector unit.
Verified technical data. Last updated: March 2026