ILLEGAL MACHINE POS.(SV)
Fanuc · αi Series Servo Amplifier
What does SV0477 mean?
The servo detected that the machine position on the axis is not within the safety area (parameter No.13831 to 13838) during safety monitoring (when the safety check request signal (*VLDVx) is 0). This indicates the axis moved outside its defined safe operating envelope after the machine reference position was established, which can lead to collisions or unsafe conditions.
Repair Steps
- 1
Confirm that parameters No.13831 to 13838 define the correct safety area for the machine.
- 2
Verify that the axis operation program ensures movement is performed within the established safety area.
- 3
Ensure the machine reference position has been correctly established for the affected axis.
Verified technical data. Last updated: March 2026
Source: Fanuc αi Series Servo Amplifier