SV0476

ILLEGAL SPEED CMD. (SV)

Fanuc · αi Series Servo Amplifier

What does SV0476 mean?

The servo detected that the commanded speed on the axis exceeded the safety speed (parameter No. 13821 to 13824, No. 13826 to 13829) during safety monitoring (when the safety check request signal (*VLDVx) is 0). This suggests an unsafe operating speed was commanded or detected, posing a potential safety risk.

Repair Steps

  1. 1

    Confirm that parameters No. 13821 to 13824 and No. 13826 to 13829 are set to appropriate safety speed values.

  2. 2

    Verify that the axis operation program ensures movement is performed within the defined safety speed limits.

  3. 3

    Check the status of the safety check request signal (*VLDVx) to ensure correct operation of safety monitoring.

Browse all codes in this manual (101)
Verified technical data. Last updated: March 2026
Source: Fanuc αi Series Servo Amplifier