ABTSP2

Second spindle abnormal load detected signal

Fanuc · i Series CNC Hardware

What does ABTSP2 mean?

This signal indicates that the second spindle of the Fanuc i Series CNC has detected an abnormal load condition. This implies the spindle motor is operating beyond its normal current limits, which can cause overheating, drive trips, or damage to the motor or mechanical components.

Common Causes

  • Excessive cutting load or tool wear.
  • Mechanical binding or obstruction within the spindle mechanism (e.g., bearings, gears).
  • Incorrect spindle drive parameters, such as torque limits or acceleration/deceleration settings.
  • Malfunctioning spindle motor or drive unit.
  • Short circuit or ground fault in the spindle motor power cable or motor windings.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Inspect the cutting tool for wear or damage and ensure correct cutting parameters are used.

  2. 2

    Check the spindle mechanics for any signs of binding, excessive friction, or damage to bearings.

  3. 3

    Monitor spindle motor current and load meter readings during operation from the Fanuc i Series CNC diagnostic display.

  4. 4

    Verify spindle drive parameters (e.g., maximum current, acceleration/deceleration times, torque limits) against machine specifications.

  5. 5

    Test the spindle motor and power cables for short circuits or ground faults using appropriate electrical testing equipment.

Browse all codes in this manual (6)
Verified technical data. Last updated: March 2026

Related Faults