0233

Velocity Pulse Count Exceeded

Fanuc · Alpha i Series Servo Amplifier

What does 0233 mean?

This invalid parameter setting alarm occurs when initialization bit 0 is set to 1, and the number of velocity pulses configured exceeds the maximum allowable value of 13100. This indicates an incorrect setup for velocity feedback, potentially leading to calculation overflows.

Common Causes

  • Expected velocity pulses not received within the defined timeframe.
  • Encoder signal interruption or degradation.
  • Motor not rotating as expected.
  • Excessive lag in velocity feedback loop.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Correct the number of velocity pulses in the relevant parameter so that its value is within 13100.

Browse all codes in this manual (101)
Verified technical data. Last updated: March 2026

Related Faults