SP0033
Converter: DC Link Precharge Failure
Fanuc · AC Spindle Motor Alpha i-Beta i Series Parameters
What does SP0033 mean?
The precharge circuit for the DC link in the converter failed to operate correctly. This can prevent the DC bus from charging to the proper voltage during startup.
Common Causes
- Faulty precharge resistor in the DC link circuit.
- Failed precharge relay or contactor.
- Error in the control logic for the precharge sequence.
- Low input voltage preventing proper precharge.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Measure DC link voltage during power-up to observe precharge behavior.
- 2
Test the precharge resistor for continuity and correct resistance value.
- 3
Verify the operation of the precharge relay or contactor.
- 4
Check control signals activating the precharge circuit.
Verified technical data. Last updated: March 2026
Related Faults
Source: Fanuc AC Spindle Motor Alpha i-Beta i Series Parameters