bAT

Keypad Battery Low Voltage

Yaskawa · V1000

¿Qué significa bAT ?

The keypad battery voltage has fallen below the acceptable threshold, indicating a low power state. If left unaddressed, this can lead to loss of real-time clock functionality or stored parameter values on the keypad. It is a precursor to complete battery failure.

Causas comunes

  • The keypad's internal battery has reached its end of life and can no longer hold sufficient charge.
  • Extended periods of the drive being powered off, causing the battery to drain without recharge (if applicable).
  • A defect in the keypad's battery charging circuit, preventing proper recharging.
  • Incorrect battery type installed (if user-replaceable), leading to rapid discharge or incompatibility.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Locate the battery compartment on the keypad (often on the rear) and carefully open it.

  2. 2

    Replace the old battery with a new, compatible type (e.g., CR2032 lithium coin cell) as specified by the manual.

  3. 3

    After battery replacement, navigate to the keypad's time and date settings and reset the real-time clock.

  4. 4

    Verify the keypad's diagnostic menu (if available) shows the battery voltage as acceptable.

  5. 5

    Ensure the keypad is properly seated and connected to the drive to allow any charging functionality to operate.