CPF20

Hardware Fault at Power Up

Yaskawa · P1000

¿Qué significa CPF20 ?

A hardware fault was detected during the initial power-up sequence of the drive, preventing it from starting correctly. This indicates a critical issue with internal components.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Measure incoming AC supply voltage at L1, L2, L3 terminals to ensure it is stable and within the drive's specified operating range.

  2. 2

    Inspect all input power and ground wiring for proper termination, tightness, and signs of damage or discoloration.

  3. 3

    Inspect motor output wiring (U, V, W) and braking resistor wiring (B1, B2) for shorts, insulation damage, or loose connections.

  4. 4

    Visually inspect the drive's internal components for any obvious signs of damage, such as burnt parts, loose debris, or liquid ingress (ensure power is off and follow LOTO procedures).