Traduciendo...
oFA09

Option Card Fault

Yaskawa · Drive Fault Codes

¿Qué significa oFA09 ?

An option card fault, indicating a general issue with one of the installed option cards. This requires corrective actions ranging from parameter adjustment to hardware checks or replacement to restore functionality of the option.

Causas comunes

  • Incorrect parameters configured for the option card (e.g., communication settings, input mapping)
  • Loose or improper installation of the option card in its slot
  • Internal malfunction of the option card hardware due to component failure or damage.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify all parameters related to the installed option card are correctly set according to the application.

  2. 2

    Perform a power cycle and then reseat the option card firmly in its slot.

  3. 3

    Check for proper operation of any external devices connected to the option card (e.g., encoder, network cable).

Ver todos los códigos en este manual (60)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas