Traduciendo...
59
Follower Communication Break
Vacon · NX Liquid-Cooled Drive
¿Qué significa 59 ?
The SystemBus or CAN communication link between the Master and Follower units in a multi-drive system is broken. This interruption prevents synchronized operation and data exchange between the connected drives.
Causas comunes
- Communication break with a follower device or module.
- Follower device offline or unresponsive.
- Communication network issue between devices.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Check the option board parameters related to SystemBus or CAN communication for correct configuration (e.g., node IDs, baud rates, communication protocols).
- 2
Inspect the optical fibre cable (for SystemBus) or CAN cable (for CAN communication) for any physical damage, breaks, or loose connections.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Vacon NX Liquid-Cooled Drive