Mechanical Brake Status Mismatch

Vacon · NX Liquid-Cooled Drive

¿Qué significa 58 ?

The actual physical status of the mechanical brake (e.g., engaged or disengaged) does not correspond to the control signal issued by the drive. This discrepancy suggests either a mechanical failure of the brake, an issue with its wiring, or a problem with the drive's brake control output.

Causas comunes

  • Actual mechanical brake status does not match the commanded status.
  • Brake activation or deactivation signal failure.
  • Brake status feedback sensor fault.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Physically inspect the mechanical brake to determine its actual engaged/disengaged state.

  2. 2

    Verify the electrical connections and wiring between the drive's brake control output and the mechanical brake actuator.

  3. 3

    Measure the voltage at the drive's brake control terminals to ensure the correct command signal is being sent.