34
CAN bus communication
Vacon · NX Liquid-Cooled Drive
¿Qué significa 34 ?
A message sent on the CAN bus was not acknowledged by another device. This typically indicates a communication problem between devices on the bus.
Causas comunes
- CAN bus communication error (e.g., bus off).
- No acknowledgement from CAN network devices.
- Incorrect CAN bus termination or cabling.
- Node ID conflict on the CAN network.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Ensure that there is at least one other active device physically present on the CAN bus.
- 2
Verify that all devices on the CAN bus have identical communication configuration, such as baud rate and node ID settings.