Traduciendo...
Grid-Timeout/Grid-Fault-S

Grid Type Detection Failure

SMA · SUNNY BOY 5000US-8000US Solar Inverter

¿Qué significa Grid-Timeout/Grid-Fault-S ?

The Sunny Boy SB50US-80US-IUS094030 inverter failed to detect the type of connected grid (208V, 240V, or 277V). This can be caused by incorrect wiring, especially when connecting to specific grid types.

Causas comunes

  • Incorrect wiring for L1 and N cables when connecting to a 277V grid.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    If connecting to a 277V grid, verify that the L1 and N cables are in the correct terminal positions.

  2. 2

    Check the condition of the grid at the AC terminal blocks within the Sunny Boy SB50US-80US-IUS094030.

  3. 3

    Inspect the AC disconnect between the Sunny Boy and the grid.

Ver todos los códigos en este manual (23)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: SMA SUNNY BOY 5000US-8000US Solar Inverter