Measuring axis not in basic/intended position
Siemens · SINUMERIK 828D
¿Qué significa 61429 ?
A measuring axis (rotary axis 1 or 2) is not in its basic or intended position, particularly during the first measurement operation. The error code A specifically indicates that rotary axis 1 is not in its basic position. This fault prevents accurate measurements from being performed.
Causas comunes
- The rotary measuring axis (e.g., C-axis on a turning machine) has not been homed or referenced to its zero position.
- Encoder feedback for the measuring axis is lost or incorrect (e.g., cable damage, encoder fault, incorrect parameter P2043 for encoder type).
- Mechanical slip or backlash in the rotary axis drive train, causing a discrepancy between commanded and actual position.
- Machine data for the rotary axis home position or limits (e.g., MD34000 to MD34005) is incorrectly set.
- External forces or collision preventing the axis from reaching its intended measuring position.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
1. Manually jog the affected rotary measuring axis (e.g., C-axis) to its reference point and perform a homing/referencing procedure (e.g., G74 or specific machine function).
- 2
2. Verify the integrity of the encoder cable for the measuring axis, checking for continuity and shielding effectiveness, and inspect the encoder feedback at the drive.
- 3
3. Check the drive parameters for the rotary axis, specifically P2043 (Encoder type) and P2044 (Encoder resolution), ensuring they match the installed encoder.
- 4
4. Observe the actual position feedback (r0030) of the rotary axis, comparing it to the commanded position, and check for any mechanical play or backlash.
- 5
5. Review machine data related to the rotary axis's home position and software limits (e.g., MD34000, MD34001) for correct configuration.