Traduciendo...
380502

PROFIBUS/PROFINET: Bus configuration changed (slave/device)

Siemens · SINUMERIK 828D

¿Qué significa 380502 ?

This alarm signals that the PROFIBUS/PROFINET bus configuration has changed, either due to initial commissioning or the recognition of a new slave/device on the bus. While not an error in itself, the new settings will only become active after a system restart. This requires a controlled restart to ensure the new configuration is properly loaded and the system operates as intended, avoiding potential communication inconsistencies.

Causas comunes

  • A new PROFIBUS slave or PROFINET device has been physically added to the network segment.
  • The GSD/GSDML file or configuration parameters for an existing slave/device have been updated in the engineering software.
  • Replacement of a PROFIBUS/PROFINET slave/device with a different model or firmware version requiring configuration adjustment.
  • The engineering software has performed a topology scan and detected a variance from the last saved configuration.
  • Memory card containing the project configuration was replaced or updated on the PLC, triggering a configuration change detection.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    1. Acknowledge the alarm in the PLC and verify if the reported configuration change corresponds to a planned modification or new device installation.

  2. 2

    2. Upload the current hardware configuration from the PLC to the engineering software to compare it with the offline project.

  3. 3

    3. If a new device was added, integrate its GSD/GSDML file and configure its parameters in the PLC project, then download the updated configuration.

  4. 4

    4. If an existing device's configuration changed, update the relevant parameters in the engineering software (e.g., I/O addresses, module types).

  5. 5

    5. Perform a 'Compare' function between the online and offline PLC project to identify the exact differences in the bus configuration.

  6. 6

    6. Initiate a complete PLC warm restart (POWER ON/OFF) if a download of the modified configuration requires a full re-initialization of the bus.

Ver todos los códigos en este manual (37)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas