Traduciendo...
F00058

BOP contents incompatible

Siemens · SINAMICS G120

¿Qué significa F00058 ?

An attempt was made to clone parameters using a Basic Operator Panel (BOP) that contains parameters created on a different type of drive. This incompatibility prevents successful parameter transfer, as the configurations are not designed for the current drive, leading to configuration errors.

Causas comunes

  • The BOP contains parameters from a different drive model or series (e.g., cloning parameters from a G120 to a G130 drive).
  • Firmware version mismatch between the drive and the BOP (e.g., older BOP firmware on a newer drive).
  • Parameter set created for a different power size or configuration of the same drive series.
  • Attempting to clone parameters with specific hardware features not present in the target drive (e.g., different I/O configuration).
  • Corruption of the parameter file on the BOP, leading to an incorrect drive type identification.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify the BOP's part number and the drive's model number to ensure they are compatible for parameter transfer.

  2. 2

    Check the firmware versions of both the drive and the BOP; update firmware if a known compatibility issue exists.

  3. 3

    Perform a factory reset of the BOP to clear its incompatible contents, then attempt to clone from the drive (if the drive has a valid configuration).

  4. 4

    Instead of cloning, try to manually input essential parameters into the drive if the BOP can still function as an interface.

  5. 5

    If parameters are being loaded from an external source (e.g., SD card, PC), ensure the parameter file matches the target drive's exact model and configuration.