Wrong safety param. data
Siemens · SINAMICS G120
¿Qué significa A01697 ?
A semaphore problem occurred during startup, preventing the drive from loading its last saved safety parameters and forcing it to load default values instead. This indicates a data integrity issue or timing problem, compromising the intended safety configuration and requiring immediate attention to restore safe operation.
Causas comunes
- Corruption of non-volatile memory where safety parameters are stored, leading to invalid data loaded at startup.
- Incomplete or interrupted save operation of safety parameters, resulting in inconsistent data being written to memory.
- Drive firmware mismatch or update issue causing safety parameter structures to be misinterpreted by the control unit.
- Electromagnetic interference (EMI) during startup causing data read errors from the internal memory module.
- Hardware defect on the control board's memory unit or safety processor, leading to persistent data integrity issues.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
1. Perform a safety parameter reset (e.g., P0970=95) and then reconfigure all safety parameters according to the machine's safety documentation.
- 2
2. Reload the safety parameters from a known good backup file using the engineering software (e.g., STARTER) and then acknowledge the changes (P0976).
- 3
3. Update the drive's firmware to the latest stable version to address any potential software bugs related to parameter storage.
- 4
4. Verify the integrity of the power supply to the drive, checking for voltage sags or interruptions during startup sequences.
- 5
5. If the issue persists after reconfiguring and reloading, consider replacing the main control board as a memory hardware fault may be present.