Traduciendo...
F07

DC link overvoltage

SEW Eurodrive · MOVITRAC 07B System

¿Qué significa F07 ?

An immediate switch-off with inhibit occurs when the DC link voltage is excessively high. This often results from too much regenerative power, issues with the braking resistor circuit (supply cable or resistance value), or a ground fault.

Causas comunes

  • DC link voltage too high
  • Excessive regenerative power
  • Issue with braking resistor circuit (supply cable or resistance value)
  • Ground fault

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Extend deceleration ramps to reduce regenerative power

  2. 2

    Check the supply cable to the braking resistor for continuity

  3. 3

    Check the technical data of the braking resistor to ensure correct value

  4. 4

    Eliminate any ground fault detected

Ver todos los códigos en este manual (41)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: SEW Eurodrive MOVITRAC 07B System