90
Assignment of motor – inverter incorrect
SEW Eurodrive · MOVIMOT MM..C
¿Qué significa 90 ?
This fault indicates a mismatch or incorrect combination between the motor and the inverter, such as pairing an MM03 inverter with a DT71D4 motor, which is not a supported configuration.
Causas comunes
- Incorrect assignment or combination of motor and inverter (e.g., MM03 – DT71D4).
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Check the combination of motor and inverter for compatibility according to SEW documentation.
- 2
Verify the assignment of the motor to the inverter.
- 3
Switch off the 24 VDC supply voltage to reset the fault.
- 4
Issue a reset command via MOVILINK®.