F109-46

Voltage supply of encoder faulty (A3403 = encoder 1 and A3404 = encoder 2)

SEW Eurodrive · MOVIDRIVE MDX60B/61B Variable Speed Drive

¿Qué significa F109-46 ?

The encoder voltage supply (A3403 or A3404) is outside the defined range (min. DC 20 V / max. DC 29 V). This can be caused by an overload in the supply voltage, potentially tripping an internal polyswitch fuse on the DCS..B option.

Causas comunes

  • Voltage supply to encoder 1 (A3403) or encoder 2 (A3404) is outside operating range.
  • Wiring fault in encoder power supply lines.
  • Defective voltage regulator for encoder power.
  • Intermittent power loss to the encoder.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check supply voltage of DCS..B option.

Ver todos los códigos en este manual (60)